{"id":55085,"date":"2025-01-20T16:09:00","date_gmt":"2025-01-20T14:09:00","guid":{"rendered":"https:\/\/pulsenmore.com\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/"},"modified":"2025-12-31T14:19:42","modified_gmt":"2025-12-31T12:19:42","slug":"pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study","status":"publish","type":"post","link":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/","title":{"rendered":"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound &#8211; A feasibility pilot study"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"55085\" class=\"elementor elementor-55085 elementor-25684\" data-elementor-post-type=\"post\">\n\t\t\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-61bc326f e-flex e-con-boxed e-con e-parent\" data-id=\"61bc326f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6bce5860 elementor-widget elementor-widget-text-editor\" data-id=\"6bce5860\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n<p>By: Ben Shitrit I., Kedmi A., El Haj K., Kosto A., Karni O., Poleg T., Bineth N., Gat T., Shnaider A., Fuchs L.,<\/p>\n\n<p class=\"has-ast-global-color-8-color has-text-color has-link-color\">Presented at: <a href=\"https:\/\/ultracon2024.eventscribe.net\/\">AIUM 2024<\/a><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d66bc9 elementor-widget elementor-widget-heading\" data-id=\"8d66bc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Objectives<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-5fc25c3 e-con-full e-flex e-con e-child\" data-id=\"5fc25c3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbe1da8 elementor-widget elementor-widget-text-editor\" data-id=\"dbe1da8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Patient-performed pulmonary ultrasound scans in a telemedicine model may be used to track the progression of pulmonary congestion, potentially reducing hospital admissions. A pilot study was conducted <\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">to assess the feasibility of hemodialysis (HD) patients using a self-operated mobile phone-based ultrasound (MPBU) device to detect pulmonary B-lines at home as an indicator of volume overload.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5302162 elementor-widget elementor-widget-heading\" data-id=\"5302162\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Methods<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8023cc elementor-widget elementor-widget-text-editor\" data-id=\"c8023cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">A prospective pilot study was conducted at a single medical center involving patients with chronic end-stage renal disease undergoing HD. Patients were recruited and trained to self-scan their lungs using the Pulsenmore-MPBU device. Self-operated scans were compared with scans performed by a physician using both the inexpensive MPBU device and a gold-standard conventional point of care ultrasound (POCUS) device (Venue Go TM, GE Healthcare).  <\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Detection of pulmonary B-lines and scan quality scores were assessed by an independent blinded sonographer, following clip shuffling to prevent order bias. We used the weighted Cohen\u2019s kappa (Kw) index to examine agreement degrees regarding B-lines classification, the Mann-Whitney U test, and Spearman&#8217;s correlation coefficient to evaluate the quality rankings. <\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">to assess the feasibility of hemodialysis (HD) patients using a self-operated mobile phone-based ultrasound (MPBU) device to detect pulmonary B-lines at home as an indicator of volume overload.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-f154b61 e-con-full e-flex e-con e-child\" data-id=\"f154b61\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f1cf75b elementor-widget elementor-widget-image\" data-id=\"f1cf75b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"418\" src=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161242.png\" class=\"attachment-large size-large wp-image-55087\" alt=\"Self-scanning of lung congestion by dialysis patients using a cellular-based ultrasound - A Pilot Study\" srcset=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161242.png 512w, https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161242-300x245.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-5adb240 e-con-full e-flex e-con e-child\" data-id=\"5adb240\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d30b693 elementor-widget elementor-widget-heading\" data-id=\"d30b693\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">EVALUATION<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-b4c2a68 e-con-full e-flex e-con e-child\" data-id=\"b4c2a68\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2e85a4e elementor-widget elementor-widget-text-editor\" data-id=\"2e85a4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Detection of lung B-lines and evaluating scan quality<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cfc6ba elementor-widget elementor-widget-image\" data-id=\"4cfc6ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"411\" height=\"488\" src=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161451.png\" class=\"attachment-large size-large wp-image-55088\" alt=\"Detection of lung B-lines and evaluating scan quality\" srcset=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161451.png 411w, https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161451-253x300.png 253w\" sizes=\"auto, (max-width: 411px) 100vw, 411px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-a273219 e-con-full e-flex e-con e-child\" data-id=\"a273219\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-75ccd23 elementor-widget elementor-widget-heading\" data-id=\"75ccd23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Results<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-561bc94 e-con-full e-flex e-con e-child\" data-id=\"561bc94\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c59806c elementor-widget elementor-widget-text-editor\" data-id=\"c59806c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">11 HD patients were recruited; 2 were excluded due to significant visual impairments ornoncooperation. During the study, 657 clips were analyzed; participants recorded 167 using the Pulsenmore MPBU device, researchers recorded 245 with the Pulsenmore-MPBU, and researchers used the Venue Go\u2122 device for 245. Mean and median follow-up was 36.33 (SD 14.85) and 32 days (IQR 23), respectively.  <\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"> <\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Before hemodialysis (HD), patients&#8217; self-operated scans and physician-operated scans, using the Pulsenmore-MPBU, showed substantial agreement in B-line count classification (N=146, Kw=0.64[95%CI:0.46\u20130.82]). Regarding the quality score rankings, there was a moderate correlation, as indicatedby a Spearman&#8217;s rs of 0.582 (N=159, p&lt; 0.001), and a difference between operators&#8217; scan quality when both using the Pulsenmore-MPBU device as shown by the Mann-Whitney U test result (U=12322,p=0.003). <\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"> <\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Before HD, when a physician operated both the Pulsenmore-MPBU device and conventional ultrasound device, there was a moderate agreement for B-line count classification (N=149, Kw=0.58[95%CI:0.41\u20130.75]).<\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"> <\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Additionally, for the quality score rankings, a moderate correlation was demonstrated between devices with a Spearman&#8217;s rs of 0.645 (N=155, p&lt; 0.001), but no difference in video quality as presented by the Mann-Whitney U test result (U=13253, p=0.53).<\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">This agreement was more substantial after HD, indicating consistent device performance with an almost perfect agreement for B-line count classification (N=57, Kw=0.81[95%CI:0.65\u20130.97]).<\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">In the quality score rankings performed by a physician, there was again a moderate correlation between devices, shown by a Spearman&#8217;s rs of 0.65 (N=62, p&lt;0.001), and similarity in video quality as presented by the Mann-Whitney U test result (U=2952, p=0.48). No adverse events were recorded during the study. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7e5f1c elementor-widget elementor-widget-image\" data-id=\"f7e5f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"663\" height=\"397\" src=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161701.png\" class=\"attachment-large size-large wp-image-55089\" alt=\"Patient vs. Physician Pulmonary edema assessment\" srcset=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161701.png 663w, https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-02-161701-300x180.png 300w\" sizes=\"auto, (max-width: 663px) 100vw, 663px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-7a0502c e-con-full e-flex e-con e-child\" data-id=\"7a0502c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-854e832 elementor-widget elementor-widget-heading\" data-id=\"854e832\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusions<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-bc4aedc e-con-full e-flex e-con e-child\" data-id=\"bc4aedc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-781cfe9 elementor-widget elementor-widget-text-editor\" data-id=\"781cfe9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Patients demonstrated the ability to self-scan their lungs at home, producing scans of satisfactory accuracy and quality for detecting pulmonary congestion. This study establishes the feasibility of using the Pulsenmore-MPBU device for self-performed ultrasound scans to monitor volume overload in HD patients. <\/span><\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"> <\/p>\n<p class=\"cvGsUA direction-ltr align-start para-style-body\"><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">The findings suggest a cost-effective telemedicine approach that could facilitate early detection of patient deterioration, potentially reducing hospital admissions and promoting patient empowerment inself-monitoring. Such outcomes could benefit not only HD patients but also other patient groups, such as those with chronic heart failure. <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>With appropriate patient selection, some older, chronically ill patients can generate high-quality LUS self-images that are non-inferior to those generated by trained physicians using the same device, thereby enabling remote detection of interstitial changes, which may indicate pulmonary congestion. The accuracy of the home ultrasound device was comparable to that of the GS device for B-line detection and the image quality of the home-device was non-inferior. <\/p>\n","protected":false},"author":11,"featured_media":55090,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":"","_links_to":"","_links_to_target":""},"categories":[196],"tags":[],"class_list":["post-55085","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-publications-and-review-articles"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound - A feasibility pilot study - PULSENMORE | Home Ultrasound<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound - A feasibility pilot study - PULSENMORE | Home Ultrasound\" \/>\n<meta property=\"og:description\" content=\"With appropriate patient selection, some older, chronically ill patients can generate high-quality LUS self-images that are non-inferior to those generated by trained physicians using the same device, thereby enabling remote detection of interstitial changes, which may indicate pulmonary congestion. The accuracy of the home ultrasound device was comparable to that of the GS device for B-line detection and the image quality of the home-device was non-inferior.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/\" \/>\n<meta property=\"og:site_name\" content=\"PULSENMORE | Home Ultrasound\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-20T14:09:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-31T12:19:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/04\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1090\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Roni Bochman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Roni Bochman\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/\"},\"author\":\"AUTHOR\",\"headline\":\"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound &#8211; A feasibility pilot study\",\"datePublished\":\"2025-01-20T14:09:00+00:00\",\"dateModified\":\"2025-12-31T12:19:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/\"},\"wordCount\":592,\"publisher\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pulsenmore.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png\",\"articleSection\":[\"Publications\"],\"inLanguage\":\"en-AU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/\",\"url\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/\",\"name\":\"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound - A feasibility pilot study - PULSENMORE | Home Ultrasound\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pulsenmore.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png\",\"datePublished\":\"2025-01-20T14:09:00+00:00\",\"dateModified\":\"2025-12-31T12:19:42+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#breadcrumb\"},\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pulsenmore.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png\",\"contentUrl\":\"https:\\\/\\\/pulsenmore.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png\",\"width\":1920,\"height\":1090,\"caption\":\"Dialysis Patients\u2019 Evaluation of Lung Edema at Home Using a Mobile Phone Tele-Ultrasound Application: A Pilot Study\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pulsenmore.com\\\/en-au\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound &#8211; A feasibility pilot study\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#website\",\"url\":\"https:\\\/\\\/pulsenmore.com\\\/\",\"name\":\"PULSENMORE | Home Ultrasound\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pulsenmore.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-AU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#organization\",\"name\":\"PULSENMORE | Home Ultrasound\",\"url\":\"https:\\\/\\\/pulsenmore.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/pulsenmore.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/home-ultrasound-logo.png\",\"contentUrl\":\"https:\\\/\\\/pulsenmore.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/home-ultrasound-logo.png\",\"width\":470,\"height\":105,\"caption\":\"PULSENMORE | Home Ultrasound\"},\"image\":{\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#\\\/schema\\\/person\\\/93c0ed2dc5d299bf242e91b6dd185480\",\"name\":\"Rachel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\",\"caption\":\"Rachel\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/pulsenmore.com\\\/#\\\/schema\\\/person\\\/93c0ed2dc5d299bf242e91b6dd185480\",\"name\":\"Rachel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-AU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g\",\"caption\":\"Rachel\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound - A feasibility pilot study - PULSENMORE | Home Ultrasound","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/","og_locale":"en_US","og_type":"article","og_title":"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound - A feasibility pilot study - PULSENMORE | Home Ultrasound","og_description":"With appropriate patient selection, some older, chronically ill patients can generate high-quality LUS self-images that are non-inferior to those generated by trained physicians using the same device, thereby enabling remote detection of interstitial changes, which may indicate pulmonary congestion. The accuracy of the home ultrasound device was comparable to that of the GS device for B-line detection and the image quality of the home-device was non-inferior.","og_url":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/","og_site_name":"PULSENMORE | Home Ultrasound","article_published_time":"2025-01-20T14:09:00+00:00","article_modified_time":"2025-12-31T12:19:42+00:00","og_image":[{"width":1920,"height":1090,"url":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/04\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png","type":"image\/png"}],"author":"Roni Bochman","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Roni Bochman","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#article","isPartOf":{"@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/"},"author":"AUTHOR","headline":"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound &#8211; A feasibility pilot study","datePublished":"2025-01-20T14:09:00+00:00","dateModified":"2025-12-31T12:19:42+00:00","mainEntityOfPage":{"@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/"},"wordCount":592,"publisher":{"@id":"https:\/\/pulsenmore.com\/#organization"},"image":{"@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#primaryimage"},"thumbnailUrl":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/04\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png","articleSection":["Publications"],"inLanguage":"en-AU"},{"@type":"WebPage","@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/","url":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/","name":"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound - A feasibility pilot study - PULSENMORE | Home Ultrasound","isPartOf":{"@id":"https:\/\/pulsenmore.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#primaryimage"},"image":{"@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#primaryimage"},"thumbnailUrl":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/04\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png","datePublished":"2025-01-20T14:09:00+00:00","dateModified":"2025-12-31T12:19:42+00:00","breadcrumb":{"@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#breadcrumb"},"inLanguage":"en-AU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/"]}]},{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#primaryimage","url":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/04\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png","contentUrl":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/04\/Dialysis-Patients-Evaluation-of-Lung-Edema-at-Home-Using-a-Mobile-Phone-Tele-Ultrasound-Application-A-Pilot-Study.png","width":1920,"height":1090,"caption":"Dialysis Patients\u2019 Evaluation of Lung Edema at Home Using a Mobile Phone Tele-Ultrasound Application: A Pilot Study"},{"@type":"BreadcrumbList","@id":"https:\/\/pulsenmore.com\/en-au\/pipline-product-self-scanning-of-lung-congestion-by-dialysis-patients-using-novel-mobile-phone-ultrasound-a-feasibility-pilot-study\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pulsenmore.com\/en-au\/home\/"},{"@type":"ListItem","position":2,"name":"Pipline product: Self-Scanning Of Lung Congestion by dialysis patients using novel mobile-phone ultrasound &#8211; A feasibility pilot study"}]},{"@type":"WebSite","@id":"https:\/\/pulsenmore.com\/#website","url":"https:\/\/pulsenmore.com\/","name":"PULSENMORE | Home Ultrasound","description":"","publisher":{"@id":"https:\/\/pulsenmore.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pulsenmore.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-AU"},{"@type":"Organization","@id":"https:\/\/pulsenmore.com\/#organization","name":"PULSENMORE | Home Ultrasound","url":"https:\/\/pulsenmore.com\/","logo":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/pulsenmore.com\/#\/schema\/logo\/image\/","url":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/05\/home-ultrasound-logo.png","contentUrl":"https:\/\/pulsenmore.com\/wp-content\/uploads\/2024\/05\/home-ultrasound-logo.png","width":470,"height":105,"caption":"PULSENMORE | Home Ultrasound"},"image":{"@id":"https:\/\/pulsenmore.com\/#\/schema\/logo\/image\/"}},{"@type":["Person","Organization"],"@id":"https:\/\/pulsenmore.com\/#\/schema\/person\/93c0ed2dc5d299bf242e91b6dd185480","name":"Rachel","image":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g","caption":"Rachel"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g"}},{"@type":"Person","@id":"https:\/\/pulsenmore.com\/#\/schema\/person\/93c0ed2dc5d299bf242e91b6dd185480","name":"Rachel","image":{"@type":"ImageObject","inLanguage":"en-AU","@id":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7ea5266b17c60e8e8ad1cdfe6a6c6805aa183a25b516795250709863b9082f19?s=96&d=mm&r=g","caption":"Rachel"}}]}},"_links":{"self":[{"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/posts\/55085","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/comments?post=55085"}],"version-history":[{"count":1,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/posts\/55085\/revisions"}],"predecessor-version":[{"id":55091,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/posts\/55085\/revisions\/55091"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/media\/55090"}],"wp:attachment":[{"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/media?parent=55085"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/categories?post=55085"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pulsenmore.com\/en-au\/wp-json\/wp\/v2\/tags?post=55085"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}